Microsoft Teams Support for Poly Trio System Feature Settings

The Microsoft Teams Administrator Portal enables you to configure settings for some Poly Trio system features. The table in this section lists the supported Poly Trio features, with configuration notes where applicable.

Table 1. General Settings
Feature Supported?
Device Lock No
Device Lock Timeout No
Device Lock PIN No
Language Yes
Time zone

Yes

The Poly Trio system converts the GMT offset (Timezone) to the closest Olson Time Zone ID, which the system uses to configure the device time zone.

Date format No
Time format Yes
Table 2. Device Settings
Feature Supported?
Display backlight brightness

Yes

The value for this setting maps to the Poly Trio system’s three discrete brightness levels.

Display backlight timeout

Yes

Poly Trio systems support a minimum timeout of 60 seconds.

Display high contrast No
Silent mode No
Office hours

Yes

Control how quickly the system display screen turns off after no user activity, as set by the display backlight timeout value. Outside of office hours, the display screen turns off after one minute.

Power saving

Yes

Control whether the display backlight turns off as set by the office hours.

Screen capture

Yes

If enabled, the Screen Capture menu displays on the Poly Trio system at Device Settings > Basic > Preferences > Screen Capture.

Table 3. Network Settings
Feature Supported?
DHCP enabled Yes
Logging enabled Yes
Host name Yes
Domain name Yes
IP address Yes
Subnet mask Yes
Default gateway Yes
Primary DNS Yes
Secondary DNS Yes
Device default admin password Yes
Network PC port Yes