Logging Schedule Parameters

The phone can be configured to schedule certain advanced logging tasks on a periodic basis.

Polycom recommends that you set the parameters listed in the next table in consultation with Polycom Technical Support. Each scheduled log task is controlled by a unique parameter set starting with log.sched.x where x identifies the task. A maximum of 10 schedule logs is allowed.

Table 1. Logging Schedule Parameters

Template

Parameter

Permitted Values

Change Causes

Restart or Reboot

techsupport.cfg

log.sched.x.level

The event class to assign to the log events generated by this command.

3 (default)

0 - 5

This needs to be the same or higher than log.level.change.slog for these events to display in the log.

No

techsupport.cfg

log.sched.x.period

Specifies the time in seconds between each command execution.

15 (default)

positive integer

No

techsupport.cfg

log.sched.x.startDay

When startMode is abs, specifies the day of the week to start command execution. 1=Sun, 2=Mon, ..., 7=Sat

7 (default)

0 - 7

No

techsupport.cfg

log.sched.x.startMode

Starts at an absolute or relative time to boot.

Null (default)

0 - 64

No

techsupport.cfg

log.sched.x.startTime

Displays the start time in seconds since boot when startMode is rel or displays the start time in 24-hour clock format when startMode is abs.

Null (default)

positive integer, hh:mm

No